Model BBLDRC9 uses RC time constant. This means that, when you are setting the DIP switches for the “baud rate”, you are setting a turnaround time, not a “baud rate”. Sometimes, the turnaround time on an RS 2-wire device does not match the turnaround time that is set on the BBLDRC9 converter. BBLDRC9. This optically isolated RS to RS/ converter features Automatic Send Data Control - no software drivers needed to control handshake lines. RS signals on DB9 female connector or terminal block. RS/ signals and power inputs connect to terminal blocks. External power required. Startco Engineering Ltd. purchases the LDRC9 from BB Electronics Ltd and modifies this component to create the SEDIN. Sections of this manual were taken from the BB Electronics publication “LDRC/3”, tables were revised to reflect our unique application. The SEDIN optically isolates and converts.


Examples of EIA to EIA converters (one to one) • CT Comms cable (CT part number ) • USB Comms cable (CT part number ) • Amplicon Fi. CT Comms cable is specifically designed to convert EIA to EIA with Control Techniques products. These converters are for one to one connection between a PC and the Commander. LDRC9 Din Rail mounted data converter. The LDRC9 optical isolated unit provides 2KV isolation, additional input power filtering and transient voltage suppressors on data lines. The converter automatically takes the Sentry RS data output and formats it to RS data for point to point transmission, or RS data. Model Number BBLDRC9 BBDRCI BBDRCI-PH BB-SCPT-DFTB3 BBOPDR BBOPDR BBOPDRI BBOPDRI Key Features Dual RS Connectors (terminal blocks DB9). NEMA TS1/TS2. Class 1/Division 2. Triple Isolation. Oil Gas Applications. Class 1/Division 2. IEC IEEE NEMA TS1/TS2. Power Utility Applications. Small Form.


Model BBLDRC9 uses RC time constant. This means that, when you are setting the DIP switches for the “baud rate”, you are setting a turnaround time, not a “baud rate”. Sometimes, the turnaround time on an RS 2-wire device does not match the turnaround time that is set on the BBLDRC9 converter. The LDRC9 is ideal for critical industrial communications, factory automation, in-cabinet conversion, warehouse automation, security, and many other applications. • Extend data up to km (4, ft.) • 2 kV optical isolation on input/output • Wide operating temperature ( to +80 °C) • Modbus compatible • UL Recognized, NEMA TS2 • Automatic Send Data Control. Product overview, Termination switch, Set the dipswitch settings for baud rate • Read online or download PDF • BB Electronics LDRC9 - Quick Start Guide User Manual.

0コメント

  • 1000 / 1000